Power Amplifier 2-6GHz 100W
1. Technical Specifications
No. | Item | Parameter |
1 | Operating Frequency (GHz) | 2-6 |
2 | Typical Power Gain (dB) | 52 |
3 | Power Flatness (dB) | ±2 |
4 | Signal Standard | Support CW, pulse signal and various types of RF modulation sources |
5 | Output Power (dBm) | ≥50 |
6 | Efficiency (%) | ≥25 |
7 | Operating Voltage (V) | +28 |
8 | Typical Quiescent Current (A) | 2 |
9 | Second Harmonic Suppression (dBc) | ≤-10 |
10 | Third Harmonic Suppression (dBc) | ≤-15 |
11 | Spurious Suppression (dBc) | ≤-70 |
12 | Input VSWR | ≤1.5 |
13 | Weight (Kg) | ≤1.2 |
14 | Operating Temperature (°C) | -40~+55 |
2. Product Functions
No. | Item | Description |
1 | Voltage Monitoring | Readable via serial port commands |
2 | Current Monitoring | Readable via serial port commands |
3 | Temperature Monitoring | Readable via serial port commands |
4 | Forward Power Monitoring | Readable via serial port commands |
5 | Reverse Power Monitoring | Readable via serial port commands |
6 | Power Supply Alarm and Protection | A voltage alarm will be triggered and the power amplifier drain power supply will be cut off when the voltage exceeds 32V, a current alarm will be triggered and the power amplifier drain power supply will be cut off when the current exceeds 25A. |
7 | Temperature Alarm | A temperature alarm will be triggered and the power amplifier drain power supply will be cut off when the module temperature exceeds 95℃. |
8 | VSWR Alarm | A VSWR alarm will be triggered and the power amplifier drain power supply will be cut off when an open circuit or short circuit is detected at the RF output port of the PA. |
9 | RS422/RS485 Serial Communication | The communication protocol follows our company's inherent protocol with a supporting upper computer program, and can be modified according to customer requirements. |
3. Interface Description
No. | Name | Connector Model | Description |
1 | RF Input | SMA-50KFD | 50 Ohms |
2 | RF Output | N-50KFD | 50 Ohms |
3 | Power and Control | J30J-21ZKN | See the interface definition table below for details |
4. Power and Control Interface Definition
No. | Name | Function | Remarks |
1 | +28V | Positive Power Supply | |
2 | +28V | Positive Power Supply | |
3 | +28V | Positive Power Supply | |
4 | +28V | Positive Power Supply | |
5 | +28V | Positive Power Supply | |
6 | +28V | Positive Power Supply | |
7 | +28V | Positive Power Supply | |
8 | +28V | Positive Power Supply | |
9 | GND | Power Ground | |
10 | GND | Power Ground | |
11 | GND | Power Ground | |
12 | GND | Power Ground | |
13 | GND | Power Ground | |
14 | GND | Power Ground | |
15 | GND | Power Ground | |
16 | GND | Power Ground | |
17 | PAEN | Enable | When the TTL signal is high, the power amplifier is turned on |
18 | RS422T+ | Serial Communication |
Compatible with 485 and 422 serial communication,4-wire (PIN18-PIN21) for RS422 communication;2-wire (PIN20-PIN21) for RS485 communication |
19 | RS422T- | Serial Communication | |
20 | RS485+/ RS422R+ | Serial Communication | |
21 | RS485-/ RS422R- | Serial Communication |
Contact: James
Phone: Collaboration13554914993
Tel: Product Inquiry17665344694
Email: market@jiffy2016.com
Add: Building 11, Dadu Industrial Zone, Bao'an District, Shenzhen